DESCRIZIONE PRODOTTO
60 Watts Single Output Industrial DIN Rail Power Supply Series
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
(English)
30 Watts Single Output Industrial DIN Rail Power Supply Series
Ci spiace, ma questo articolo è disponibile soltanto in Inglese Americano. Per ragioni di convenienza del visitatore, il contenuto è mostrato sotto nella lingua alternativa. Puoi cliccare sul link per cambiare la lingua attiva.
60 Watts Single Output Industrial DIN Rail Power Supply Series
(English)
MODEL | IT-DIN-60S-12 | IT-DIN-60S-24 | IT-DIN-60S-48 | ||
---|---|---|---|---|---|
OUTPUT | DC Output | 12V | 24V | 48V | |
Rated Current | 5A | 2.5A | 1.25A | ||
Current Range Note 1 | 0~5A | 0~2.5A | 0~1.25A | ||
Ripple and Noise | 10~50℃ | ≤60mV | ≤50mV | ≤120mV | |
Note 2 | .-25~10℃ | ≤120mV | ≤100mV | ≤240mV | |
Voltage ADJ. Range | 12~14V | 24~28V | 48~56V | ||
Voltage Accuracy | ±1.0% | ||||
Line Regulation | ±0.5% | ||||
Load Regulation | ±1% | ||||
Set-up Time | <1.5S @230Vac Full load | ||||
Hold up Time | ≥20mS @230Vac Full load | ||||
Temperature Coefficient | ±0.03%/℃ | ||||
Overshoot and undershoot | <5.0% | ||||
INPUT | Voltage Range | 90Vac~264Vac, 127VDC-370VDC(input V+ connect L, input V- connect N) | |||
Frequency Range | 47Hz~63Hz | ||||
Efficiency ( Typical) @ 230Vac | 0.86 | 0.88 | 0.89 | ||
AC Current (max.) | <1.6A | ||||
Inrush Current (Typical) | 65A/230Vac Cold start | 50A/230Vac Cold start | 65A/230Vac Cold start | ||
Leakage Current | Input—output: ≤0.25mA Input—PE: ≤3.5mA | ||||
PROTECTION | Over Load | 6~7.5A | 3~4A | 1.5~2.5A | |
Hiccup mode, auto recovery | Hiccup mode, auto recovery | Hiccup mode, auto recovery | |||
Over voltage | 15.4~18V | 28.8~31.2V | 58~63V | ||
Hiccup mode, auto recovery | Hiccup mode, auto recovery | Hiccup mode, auto recovery | |||
Short Circuit | Long-term mode, auto recovery | ||||
ENVIRONMENT | Operating amb. Temp. & Hum. | .-25℃~50℃; 20%~90%RH No condensing | |||
Storage Temp. & Hum. | .-40℃~85℃; 5%~95%RH No condensing | ||||
SAFETY &EMC | Safety Standards | UL60950, EN60950 | |||
Note 3 | Withstand Voltage | Primary-Secondary: 3KVac/10mA; Primary-PE: 1.5KVac/10mA; Secondary-PE: 0.5KVac/10mA | |||
Isolation Resistance | >10M ohms | ||||
EMC Emission | Compliance to EN55022, EN55024 Class B | ||||
Harmonic Current | Compliance to EN61000-3-2 , CLASS A | ||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level | ||||
OTHERS | MTBF (MIL-HDBK-217F) | 590,000Hrs (25℃, Full load) | |||
Dimension (L*W*H) | 103.7*32*97.5mm | ||||
Packing | 36pcs/CTN | ||||
Cooling method | Cooling by free air convection | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25 ℃ of ambient temperature. | ||||
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. . |
24-ports 100Base-FX (SC/ST/FC) + 4-ports Gigabit (SFP slot) Managed Industrial Ethernet Switch.
The IT-ES5028-IM-4GS-24F is an industrial grade, managed and redundancy Ethernet switch which supports 24 Ethernet Ports and 4 Gigabit (SFP slot) ports. It provided some kinds of advanced network managed function, like as: SW-Ring™ redundancy ring network, VLAN, Trunking, Quality of Service, Speed control, port mirroring, fault alarm and firmware upgrade online. SW-Ring™ can bring your Ethernet to intelligent redundancy. Standard Industry design can satisfied every requirement of the industry scene. All components used industry grade, it takes products high reliability. It provided wide voltage power supply input.
SW-Ring™ is an arithmetic designed as a rapid redundancy network. It provided recover technology for fault of rapid redundant network, the recovery time<20ms. Product accorded to CE, FCC standard and Industry grade 4 design requirement, support 1 channel power input and 1 channel relay alarm output, and -40~75℃working temperature, can meet all kinds of Industrial environment requirement. It can use in power, water conservancy, transportation area, etc.
4-ports 10/100M Ethernet + 20-ports 100Base-FX (SC/ST/FC) Managed Industrial Ethernet Switch.
The IT-ES5024-IM-20F is an industrial grade, managed and redundancy Ethernet switch which supports 4 Ethernet Ports and 20 Fiber ports. It provided some kinds of advanced network managed function, like as: SW-Ring™ redundancy ring network, VLAN, Trunking, Quality of Service, Speed control, port mirroring, fault alarm and firmware upgrade online. SW-Ring™ can bring your Ethernet to intelligent redundancy. Standard Industry design, can satisfied every requirement of the industry scene. All components used industry grade, it takes products high reliability. It provided wide voltage power supply input.
Product complies with FCC and CE standards, in line with the industrial design requirements, for intelligent substation construction provides high-performance, high-quality products guaranteed. Support 1 channel power inputs and 1 relay alarm output, wide temperature range of -40~75℃ to be able to meet the requirements of all kinds of industrial field, can be widely used in electric power, water conservancy, transportation, and other fields.
360 Watts Single Output Industrial DIN Rail Power Supply Series
12-ports 10/100M Ethernet + 4-ports 100Base-FX(SC/ST/FC) Managed Industrial Ethernet Switch.
The IT-ES6116-IM-4F is an industrial grade, managed and redundancy Ethernet switch which supports 12 Ethernet ports and 4 Fiber ports. It provided some kinds of advanced network managed function, like as: SW-Ring™ redundancy ring network, VLAN, Trunking, Quality of Service, Speed control, port mirroring, fault alarm and firmware upgrade online. Standard Industry design, can satisfied every requirement of the industry scene. All components used industry grade, it takes products high reliability.
SW-Ring™ is an arithmetic designed as a rapid redundancy network. It provided recover technology for fault of rapid redundant network, the recovery time<20ms. Product accorded to CE, FCC standard and Industry grade 4 design requirement, support 2 redundant power input and 1 channel relay alarm output, and -40~75°C working temperature, can meet all kinds of Industrial environment requirement.