(English) IT-EMC-35S Series
(English)
35 Watts Single Output Series
- No Load power consumption<0.5W
- Universal AC input range
- Miniature size, high power density, high efficiency, long life and high reliability
- Withstand 300VA surge input for 5 sec.
- Output protections: OLP/OPP/SCP
- Wide operating ambient temp (-20℃~70℃)
- Operating altitude up to 5000M
- All using 105℃ long life electrolytic capacitors.
- 100% full load burn-in test
- Easy assembling from top side
- PCB soldering side with conformal coating
- Suitable for critical applications
- 3 years warranty
Condividi su:
- Fai clic qui per condividere su LinkedIn (Si apre in una nuova finestra)
- Fai clic per condividere su Facebook (Si apre in una nuova finestra)
- Fai clic qui per condividere su Pinterest (Si apre in una nuova finestra)
- Fai clic qui per condividere su Twitter (Si apre in una nuova finestra)
- Fai clic per condividere su WhatsApp (Si apre in una nuova finestra)
- Fai clic qui per condividere su Reddit (Si apre in una nuova finestra)
- Fai clic qui per condividere su Tumblr (Si apre in una nuova finestra)
- Fai clic per condividere su Telegram (Si apre in una nuova finestra)
- Fai clic qui per condividere su Pocket (Si apre in una nuova finestra)
- Fai clic per inviare un link a un amico via e-mail (Si apre in una nuova finestra)
- Fai clic qui per stampare (Si apre in una nuova finestra)
- Descrizione
- Specifiche Tecniche
- Diagrammi a Blocchi
- Grafici e Curve
- Disegni Meccanici
- Documenti / Download
- Contattaci / Richieste
Descrizione
Ci spiace, ma questo articolo è disponibile soltanto in English.
35 Watts Single Output Series
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
(English)
TECHNICAL SPECIFICATIONS
MODEL | IT-EMC-35S-5 | IT-EMC-35S-12 | IT-EMC-35S-15 | ||
---|---|---|---|---|---|
OUTPUT | DC Output | 5V | 12V | 15V | |
Rated Current | 6A | 3A | 2.4A | ||
Current Range | 0~6A | 0~3A | 0~2.4A | ||
Ripple and Noise Note 2 | 0~70℃ | <50mV | <80mV | <120mV | |
.-25~0℃ | <80mV | <180mV | <200mV | ||
Voltage ADJ. Range | -5%~+10% of rated output voltage | ||||
Voltage Accuracy | ±3.0% | ±3.0% | ±3.0% | ||
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ||
Load Regulation | ±1.0% | ±1.0% | ±1.0% | ||
Set-up Time | < 1S (230Vac input, Full load); | ||||
Hold up Time | > 20mS (230Vac input, Full load); > 10mS (120Vac input, Full load) | ||||
Temperature Coefficient | ±0.03%/℃ | ||||
Overshoot and Undershoot | <5.0% | ||||
INPUT | Voltage Range | 90Vac~264Vac , 127~370Vdc | |||
Frequency Range | 47Hz~63Hz | ||||
Efficiency | 115Vac input | 0.79 | 0.83 | 0.85 | |
( Typical) | 230Vac input | 0.8 | 0.84 | 0.86 | |
AC Current (max.) | <1A(max) | ||||
Inrush Current (Typical) | <50A@230Vac Cold start | ||||
Leakage Current | Input—output:<3.5mA Input—PG:<0.25mA | ||||
PROTECTION | Over Load | 105%~150% of rated output current, constant power,auto recovery | |||
Over Voltage | 105%~150% of rated output voltage, Constant Voltage | ||||
Short Circuit | Long-term mode, auto recovery | ||||
ENVIRONMENT | Operating amb. Temp. & Hum. | .-25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) | |||
Storage Temp. & Hum. | .-40℃~85℃; 10%~95%RH No condensing | ||||
SAFETY &EMC | Safety Standards | UL60950-1 2 nd Ed; IEC 60950-1:2005(2 nd Ed); EN60950-1:2006 | |||
Note 3 | Withstand Voltage | Primary-Secondary: 3.0KVac; ≤10mA. Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤ 10mA. | |||
Isolation Resistance | ≥100M ohms | ||||
EMC Emission | Compliance to EN55022, EN55024 ClassB | ||||
Harmonic Current | Compliance to EN61000-3-2,-3 | ||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, EN61000-6-2 heavy industry level | ||||
OTHERS | MTBF (MIL-HDBK-217F) | More than 200,000Hrs (25℃, Full load) | |||
Dimension (L*W*H) | 101.6×63.5×33mm | ||||
Packing | 60PCS/CTN, 15.18KGS, 0.06CBM | ||||
Cooling method | Cooling by free air convection |
MODEL | IT-EMC-35S-24 | IT-EMC-35S-48 | ||
---|---|---|---|---|
OUTPUT | DC Output | 24V | 48V | |
Rated Current | 1.5A | 0.76A | ||
Current Range | 0~1.5A | 0~0.76A | ||
Ripple and Noise Note 2 | 0~70℃ | <120mV | <180 mV | |
.-25~0℃ | <200mV | <240mV | ||
Voltage ADJ. Range | -5%~+10% of rated output voltage | |||
Voltage Accuracy | ±3.0% | ±3.0% | ||
Line Regulation | ±0.5% | ±0.5% | ||
Load Regulation | ±1.0% | ±1.0% | ||
Set-up Time | < 1S (230Vac input, Full load); | |||
Hold up Time | > 20mS (230Vac input, Full load); > 10mS (120Vac input, Full load) | |||
Temperature Coefficient | ±0.03%/℃ | |||
Overshoot and Undershoot | <5.0% | |||
INPUT | Voltage Range | 90Vac~264Vac , 127~370Vdc | ||
Frequency Range | 47Hz~63Hz | |||
Efficiency | 115Vac input | 0.86 | 0.87 | |
( Typical) | 230Vac input | 0.87 | 0.88 | |
AC Current (max.) | <1A(max) | |||
Inrush Current (Typical) | <50A@230Vac Cold start | |||
Leakage Current | Input—output:<3.5mA Input—PG:<0.25mA | |||
PROTECTION | Over Load | 105%~150% of rated output current, constant power,auto recovery | ||
Over Voltage | 105%~150% of rated output voltage, Constant Voltage | |||
Short Circuit | Long-term mode, auto recovery | |||
ENVIRONMENT | Operating amb. Temp. & Hum. | .-25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) | ||
Storage Temp. & Hum. | .-40℃~85℃; 10%~95%RH No condensing | |||
SAFETY &EMC | Safety Standards | UL60950-1 2 nd Ed; IEC 60950-1:2005(2 nd Ed); EN60950-1:2006 | ||
Note 3 | Withstand Voltage | Primary-Secondary: 3.0KVac; ≤10mA. Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤ 10mA. | ||
Isolation Resistance | ≥100M ohms | |||
EMC Emission | Compliance to EN55022, EN55024 ClassB | |||
Harmonic Current | Compliance to EN61000-3-2,-3 | |||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, EN61000-6-2 heavy industry level | |||
OTHERS | MTBF (MIL-HDBK-217F) | More than 200,000Hrs (25℃, Full load) | ||
Dimension (L*W*H) | 101.6×63.5×33mm | |||
Packing | 60PCS/CTN, 15.18KGS, 0.06CBM | |||
Cooling method | Cooling by free air convection |
NOTES:
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
Datasheet Prodotto
Prodotti correlati
-
(English) IT-DIN-480 Series
(English)- Leggi tutto480 Watts Single Output Industrial DIN Rail Power Supply Series
- Universal AC input range(85~264Vac)
- Support 1+1 or N+1 redundant system(suggest to use redundancy modules.)
- Built-in active PFC,PF>0.95
- High efficiency up to 91%
- Built-in current sharing function
- Built-in current limiting circuit
- Output protections: OVP/OLP/SCP/OTP
- Wide operating ambient temp (-25℃~70℃)
- 150% peak load capacity
- Easy Fuse Tripping due to High Overload Current
- Excellent Partial Load Efficiency
- Built-in DC OK relay contact
- Can be installed on TS-35/7.5 or TS-35/15
- 100% full load burn-in test
- Suitable for critical applications
- Ultra-slim,32mm width
- 3 years warranty
-
IT-232D
(English)- Leggi tuttoIT-232D is a kind of RS-232 system communication extending product. This type of product auto sense serial rate transmission rate, no external power needed, optic electric isolation 2500V, be applicable in tough environment. Transmission distance at 9,600bps is 2,000m, stable performance. IT-232D has 2500 volts of isolation twice the rating of most isolators to protect RS-232 equipment from lightning strikes, accidental high voltage shorts and ground loops.
-
(English) IT-232-CAN
(English)- Leggi tuttoIT-232-CAN is used for data exchange between CAN-Bus field bus and RS-232 bus interface converter, and supports Modbus RTU protocol. IT-232-CAN interface converter integrated a RS-232 channel and a CAN-Bus channel can be easily embedded using RS-232 interface for communication nodes, do not need to change the original hardware architecture enables the device to obtain the CAN-Bus communication interface, to achieve between the equipments of RS-232 and CAN-Bus network connection and data communication. RS-232 channel IT-232-CAN devices to support a variety of baud rate, the range is 300bps~115200bps. CAN-Bus channel support CiA recommended a variety of standard baud rate and user-defined baud rate, the range of 2.5Kbps~1Mbps. IT-232-CAN interface converter provides three types of data conversion: transparent conversion, encryption conversion and Modbus protocol conversion. Its exterior design supports DIN-Rail mounting and Wall mounting, which is convenient for engineering application. The board comes with a photoelectric isolation module, complete electrical isolation control circuit and CAN-Bus communication circuit, so that the IT-232-CAN converter has a strong anti-interference ability, greatly improving the system in the harsh environment of the use of reliability.
-
(English) IT-DIN-360 Series
(English)- Leggi tutto360 Watts Single Output Industrial DIN Rail Power Supply Series
- Universal AC input range(85~264Vac)
- Support 1+1 or N+1 redundant system(suggest to use redundancy modules.)
- Built-in active PFC,PF>0.95
- High efficiency up to 93%
- Built-in current sharing function
- Built-in current limiting circuit
- Output protections: OVP/OLP/SCP/OTP
- Wide operating ambient temp (-25℃~70℃)
- 150% peak load capacity
- Excellent Partial Load Efficiency
- Built-in DC OK relay contact
- Can be installed on TS-35/7.5 or TS-35/15
- 100% full load burn-in test
- Suitable for critical applications
- Ultra-slim, 50mm width
- Free air convection
- 3 years warranty