(English) IT-EMC-35S Series
(English)
35 Watts Single Output Series
- No Load power consumption<0.5W
- Universal AC input range
- Miniature size, high power density, high efficiency, long life and high reliability
- Withstand 300VA surge input for 5 sec.
- Output protections: OLP/OPP/SCP
- Wide operating ambient temp (-20℃~70℃)
- Operating altitude up to 5000M
- All using 105℃ long life electrolytic capacitors.
- 100% full load burn-in test
- Easy assembling from top side
- PCB soldering side with conformal coating
- Suitable for critical applications
- 3 years warranty
Condividi su:
- Condividi su LinkedIn (Si apre in una nuova finestra) LinkedIn
- Condividi su Facebook (Si apre in una nuova finestra) Facebook
- Condividi su Pinterest (Si apre in una nuova finestra) Pinterest
- Condividi su X (Si apre in una nuova finestra) X
- Condividi su WhatsApp (Si apre in una nuova finestra) WhatsApp
- Condividi su Reddit (Si apre in una nuova finestra) Reddit
- Condividi su Tumblr (Si apre in una nuova finestra) Tumblr
- Condividi su Telegram (Si apre in una nuova finestra) Telegram
- Condividi su Pocket (Si apre in una nuova finestra) Pocket
- Invia un link a un amico via e-mail (Si apre in una nuova finestra) E-mail
- Stampa (Si apre in una nuova finestra) Stampa
- Description
- Specifiche Tecniche
- Diagrammi a Blocchi
- Grafici e Curve
- Disegni Meccanici
- Documenti / Download
- Contattaci / Richieste
Description
Ci spiace, ma questo articolo è disponibile soltanto in English.
35 Watts Single Output Series
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
(English)
TECHNICAL SPECIFICATIONS
| MODEL | IT-EMC-35S-5 | IT-EMC-35S-12 | IT-EMC-35S-15 | ||
|---|---|---|---|---|---|
| OUTPUT | DC Output | 5V | 12V | 15V | |
| Rated Current | 6A | 3A | 2.4A | ||
| Current Range | 0~6A | 0~3A | 0~2.4A | ||
| Ripple and Noise Note 2 | 0~70℃ | <50mV | <80mV | <120mV | |
| .-25~0℃ | <80mV | <180mV | <200mV | ||
| Voltage ADJ. Range | -5%~+10% of rated output voltage | ||||
| Voltage Accuracy | ±3.0% | ±3.0% | ±3.0% | ||
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ||
| Load Regulation | ±1.0% | ±1.0% | ±1.0% | ||
| Set-up Time | < 1S (230Vac input, Full load); | ||||
| Hold up Time | > 20mS (230Vac input, Full load); > 10mS (120Vac input, Full load) | ||||
| Temperature Coefficient | ±0.03%/℃ | ||||
| Overshoot and Undershoot | <5.0% | ||||
| INPUT | Voltage Range | 90Vac~264Vac , 127~370Vdc | |||
| Frequency Range | 47Hz~63Hz | ||||
| Efficiency | 115Vac input | 0.79 | 0.83 | 0.85 | |
| ( Typical) | 230Vac input | 0.8 | 0.84 | 0.86 | |
| AC Current (max.) | <1A(max) | ||||
| Inrush Current (Typical) | <50A@230Vac Cold start | ||||
| Leakage Current | Input—output:<3.5mA Input—PG:<0.25mA | ||||
| PROTECTION | Over Load | 105%~150% of rated output current, constant power,auto recovery | |||
| Over Voltage | 105%~150% of rated output voltage, Constant Voltage | ||||
| Short Circuit | Long-term mode, auto recovery | ||||
| ENVIRONMENT | Operating amb. Temp. & Hum. | .-25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) | |||
| Storage Temp. & Hum. | .-40℃~85℃; 10%~95%RH No condensing | ||||
| SAFETY &EMC | Safety Standards | UL60950-1 2 nd Ed; IEC 60950-1:2005(2 nd Ed); EN60950-1:2006 | |||
| Note 3 | Withstand Voltage | Primary-Secondary: 3.0KVac; ≤10mA. Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤ 10mA. | |||
| Isolation Resistance | ≥100M ohms | ||||
| EMC Emission | Compliance to EN55022, EN55024 ClassB | ||||
| Harmonic Current | Compliance to EN61000-3-2,-3 | ||||
| EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, EN61000-6-2 heavy industry level | ||||
| OTHERS | MTBF (MIL-HDBK-217F) | More than 200,000Hrs (25℃, Full load) | |||
| Dimension (L*W*H) | 101.6×63.5×33mm | ||||
| Packing | 60PCS/CTN, 15.18KGS, 0.06CBM | ||||
| Cooling method | Cooling by free air convection |
| MODEL | IT-EMC-35S-24 | IT-EMC-35S-48 | ||
|---|---|---|---|---|
| OUTPUT | DC Output | 24V | 48V | |
| Rated Current | 1.5A | 0.76A | ||
| Current Range | 0~1.5A | 0~0.76A | ||
| Ripple and Noise Note 2 | 0~70℃ | <120mV | <180 mV | |
| .-25~0℃ | <200mV | <240mV | ||
| Voltage ADJ. Range | -5%~+10% of rated output voltage | |||
| Voltage Accuracy | ±3.0% | ±3.0% | ||
| Line Regulation | ±0.5% | ±0.5% | ||
| Load Regulation | ±1.0% | ±1.0% | ||
| Set-up Time | < 1S (230Vac input, Full load); | |||
| Hold up Time | > 20mS (230Vac input, Full load); > 10mS (120Vac input, Full load) | |||
| Temperature Coefficient | ±0.03%/℃ | |||
| Overshoot and Undershoot | <5.0% | |||
| INPUT | Voltage Range | 90Vac~264Vac , 127~370Vdc | ||
| Frequency Range | 47Hz~63Hz | |||
| Efficiency | 115Vac input | 0.86 | 0.87 | |
| ( Typical) | 230Vac input | 0.87 | 0.88 | |
| AC Current (max.) | <1A(max) | |||
| Inrush Current (Typical) | <50A@230Vac Cold start | |||
| Leakage Current | Input—output:<3.5mA Input—PG:<0.25mA | |||
| PROTECTION | Over Load | 105%~150% of rated output current, constant power,auto recovery | ||
| Over Voltage | 105%~150% of rated output voltage, Constant Voltage | |||
| Short Circuit | Long-term mode, auto recovery | |||
| ENVIRONMENT | Operating amb. Temp. & Hum. | .-25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) | ||
| Storage Temp. & Hum. | .-40℃~85℃; 10%~95%RH No condensing | |||
| SAFETY &EMC | Safety Standards | UL60950-1 2 nd Ed; IEC 60950-1:2005(2 nd Ed); EN60950-1:2006 | ||
| Note 3 | Withstand Voltage | Primary-Secondary: 3.0KVac; ≤10mA. Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤ 10mA. | ||
| Isolation Resistance | ≥100M ohms | |||
| EMC Emission | Compliance to EN55022, EN55024 ClassB | |||
| Harmonic Current | Compliance to EN61000-3-2,-3 | |||
| EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, EN61000-6-2 heavy industry level | |||
| OTHERS | MTBF (MIL-HDBK-217F) | More than 200,000Hrs (25℃, Full load) | ||
| Dimension (L*W*H) | 101.6×63.5×33mm | |||
| Packing | 60PCS/CTN, 15.18KGS, 0.06CBM | |||
| Cooling method | Cooling by free air convection |
NOTES:
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
Datasheet Prodotto
Related products
-

(English) IT-DIN-480 Series
(English)- Read more480 Watts Single Output Industrial DIN Rail Power Supply Series
- Universal AC input range(85~264Vac)
- Support 1+1 or N+1 redundant system(suggest to use redundancy modules.)
- Built-in active PFC,PF>0.95
- High efficiency up to 91%
- Built-in current sharing function
- Built-in current limiting circuit
- Output protections: OVP/OLP/SCP/OTP
- Wide operating ambient temp (-25℃~70℃)
- 150% peak load capacity
- Easy Fuse Tripping due to High Overload Current
- Excellent Partial Load Efficiency
- Built-in DC OK relay contact
- Can be installed on TS-35/7.5 or TS-35/15
- 100% full load burn-in test
- Suitable for critical applications
- Ultra-slim,32mm width
- 3 years warranty
-

(English) IT-IPS-318-IU-4-POE
(English)- Read more4-ports 10/100Base-T(x) (POE) + 4-ports 10/100Base-T(x).
IT-IPS-318-IU-4-POE is an industrial grade, unmanaged PoE switch. The switch provides 4 ports 10/100 Base-T(x) PoE and 4 port 10/100Base-T(x) Ethernet, that PoE port supports POE function (IEEE802.3af/at). The switches are classified as power source equipment (PSE), and when used in this way, the switches enable centralization of the power supply, providing up to 30 watts of power per port and reducing the effort needed for installing power. The switches can be used to power IEEE 802.3af/at standard devices (PD), eliminating the need for additional wiring.
It support CE, FCC standard, adopt industry standard design, IP40 protection, rugged high-strength metal case, power supply input (48VDC). The switch support IEEE802.3/ IEEE802.3u/ IEEE802.3x/ with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing, the -40~75℃ working temperature, can meet all kinds of Industrial environment requirement, providing reliable and economic solution for your industrial Ethernet network.
-

(English) IT-IPS-316-IU-2GC-4-POE
(English)- Read more4-ports 10/100Base-T(x) (POE) + 2-ports Gigabit Combo.
IT-IPS-316-IU-2GC-4-POE is an industrial grade, unmanaged Ethernet switch. The switch provides 4 ports 10/100M Ethernet and 2 ports combo Gigabit SFP slots or 10/100/1000Base-T(X) ports, which 4 ports Ethernet supports POE function (IEEE802.3af/at). The switches are classified as power source equipment (PSE), and when used in this way, the switches enable centralization of the power supply, providing up to 30 watts of power per port and reducing the effort needed for installing power. The switches can be used to power IEEE 802.3af/at standard devices (PD), eliminating the need for additional wiring.
It support CE, FCC standard, adopt industry standard design, IP40 protection, rugged high-strength metal case, power supply input (48VDC). The -40~75℃ working temperature, can meet all kinds of Industrial environment requirement, providing reliable and economic solution for your industrial Ethernet network.
-

(English) IT-DIN-360 Series
(English)- Read more360 Watts Single Output Industrial DIN Rail Power Supply Series
- Universal AC input range(85~264Vac)
- Support 1+1 or N+1 redundant system(suggest to use redundancy modules.)
- Built-in active PFC,PF>0.95
- High efficiency up to 93%
- Built-in current sharing function
- Built-in current limiting circuit
- Output protections: OVP/OLP/SCP/OTP
- Wide operating ambient temp (-25℃~70℃)
- 150% peak load capacity
- Excellent Partial Load Efficiency
- Built-in DC OK relay contact
- Can be installed on TS-35/7.5 or TS-35/15
- 100% full load burn-in test
- Suitable for critical applications
- Ultra-slim, 50mm width
- Free air convection
- 3 years warranty

English



RSS - Articoli
Warning: Undefined variable $user_ID in /web/htdocs/www.intellisystem.it/home/Intellisystem/wp-content/themes/sportlife/comments.php on line 83