(English) IT-DIN-960 Series
(English)
960 Watts Single Output Industrial DIN Rail Power Supply Series
- Universal AC input range(85~264Vac)
- Support 1+1 or N+1 redundant system(suggest to use redundancy modules.)
- Built-in active PFC,PF≥0.98
- High efficiency up to 94.5%
- Built-in current sharing function
- Built-in current limiting circuit
- Output protections: OVP/OLP/SCP/OTP
- Wide operating ambient temp (-25℃~70℃)
- Altitude up to 6000m
- 150% peak load capacity
- Easy Fuse Tripping due to High Overload Current
- Built-in DC OK relay contact
- Remote control output voltage
- Internal fault diagnose through LED light
- Can be installed on TS-35/7.5 or TS-35/15
- 100% full load burn-in test
- PCB soldering side with conformal coating
- Suitable for critical applications
- Ultra-slim,140mm width
- Free air convection
- 3 years warranty
Condividi su:
- Fai clic qui per condividere su LinkedIn (Si apre in una nuova finestra)
- Fai clic per condividere su Facebook (Si apre in una nuova finestra)
- Fai clic qui per condividere su Pinterest (Si apre in una nuova finestra)
- Fai clic qui per condividere su Twitter (Si apre in una nuova finestra)
- Fai clic per condividere su WhatsApp (Si apre in una nuova finestra)
- Fai clic qui per condividere su Reddit (Si apre in una nuova finestra)
- Fai clic qui per condividere su Tumblr (Si apre in una nuova finestra)
- Fai clic per condividere su Telegram (Si apre in una nuova finestra)
- Fai clic qui per condividere su Pocket (Si apre in una nuova finestra)
- Fai clic per inviare un link a un amico via e-mail (Si apre in una nuova finestra)
- Fai clic qui per stampare (Si apre in una nuova finestra)
- Descrizione
- Specifiche Tecniche
- Diagrammi a Blocchi
- Metodi di Montaggio
- Diagrammi Schematici
- Grafici e Curve
- Disegni Meccanici
- Documenti / Download
- Contattaci / Richieste
Descrizione
Ci spiace, ma questo articolo è disponibile soltanto in English.
960 Watts Single Output Industrial DIN Rail Power Supply Series
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
(English)
TECHNICAL SPECIFICATIONS
MODEL | DG-960-24 | DG-960-48 | ||
---|---|---|---|---|
OUTPUT | DC Output | 24V | 48V | |
Rated Current | 40A | 10A | ||
Current Range Note 1 | 0~40A | 0~10A | ||
Ripple and Noise | 0~70℃ | ≤240mV | ≤480mV | |
Note 2 | .-25℃ | ≤480mV | ≤480mV | |
Voltage ADJ. Range | 24~28V | 48~56V | ||
Voltage Accuracy | ±3.0% | |||
Line Regulation | ±0.5% | |||
Load Regulation | ±1.0% | |||
Set-up Time | <1S@230VAC <2S@100VAC full load | |||
Hold up Time | ≥20mS(230Vac input, Full load) | |||
Temperature Coefficient | ±0.03%/ ℃ | |||
Overshoot and Undershoot | <5.0% | |||
INPUT | Voltage Range | 85Vac~264Vac, 220Vdc-370Vdc | ||
Frequency Range | 47Hz~63Hz | |||
Power Factor (typical) | 0.99/100Vac 0.98/230Vac full load | |||
Efficiency ( Typical) @ 230Vac | 94.4% | 93.8% | ||
≥84% | ||||
≥88% | ||||
AC Current (max.) | <11 A/100Vac <5.0A/230Vac | |||
Inrush Current (Typical) | < 30A/100Vac < 60A/230Vac Cold start | |||
Leakage Current | ≤1.18mA/2.82mA TN- TT-mains/IT-mains (264Vac input, 50Hz) | |||
PROTECTION | Over Load | 110%~150% of rated current, Constant current limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery | ||
Over voltage | 29~33V, hiccup mode, Auto recovery | 58~63V, constant voltage, Auto recovery | ||
Over temperature | 115±5℃, detect on temperature controller; shut down O/P, auto recovery after temperature goes down. | |||
Short Circuit | Long-term mode, auto recovery | |||
ENVIRONMENT | Operating amb. Temp. & Hum. | .-25℃~70℃; 20%~90%RH No condensing D40 | ||
Storage Temp. & Hum. | .-40℃~85℃; 5%~95%RH No condensing | |||
SAFETY &EMC | Safety Standards | meet UL508, UL60950, EN60950 | ||
Withstand Voltage | Primary-Secondary: 3.0KVac/20mA .Primary-PG: 2.5KVac/20mA. Secondary-PG: 0.5KVac/40mA. | |||
Output-DC OK: 0.5KVac/1mA | ||||
Isolation Resistance | 10M ohms | |||
EMC Emission | Compliance to EN55022, EN55024, FCC PART 15 CLASS A | |||
Harmonic Current | Compliance to EN61000-3-2, CLASS A | |||
OTHERS | EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level | ||
MTBF (MIL-HDBK-217F) | More than 300,000Hrs (25℃, Full load) MIL-217 Method 2 Components Stress Method | |||
Dimension (L*W*H) | 140*124.6*138.2mm | |||
Packing | 6pcs/CTN, 15Kgs/CTN, 0.04cbm |
Datasheet Prodotto
Prodotti correlati
-
(English) IT-ES6116-IM-2F
(English)- Leggi tutto14-ports 10/100M Ethernet + 2-ports 100Base-FX(SC/ST/FC) Managed Industrial Ethernet Switch.
The IT-ES6116-IM-2F is an industrial grade, managed and redundancy Ethernet switch which supports 14 Ethernet ports and 2 Fiber ports. It provided some kinds of advanced network managed function, like as: SW-Ring™ redundancy ring network, VLAN, Trunking, Quality of Service, Speed control, port mirroring, fault alarm and firmware upgrade online. Standard Industry design can satisfied every requirement of the industry scene. All components used industry grade, it takes products high reliability.
SW-Ring™ is an arithmetic designed as a rapid redundancy network. It provided recover technology for fault of rapid redundant network, the recovery time<20ms. Product accorded to CE, FCC standard and Industry grade 4 design requirement, support 2 redundant power input and 1 channel relay alarm output, and -40~75°C working temperature, can meet all kinds of Industrial environment requirement.
-
IT-ES7110-IM-2GS-4F
(English)- Leggi tutto6-ports 10/100M Ethernet + 2-ports 100Base-FX(SC/ST) + 2-ports gigabit (SFP) slot) Managed Industrial Ethernet Switch.
The IT-ES7110-IM-2GS-4F is an industrial grade, managed and redundancy Ethernet switch. It provided some kinds of advanced network managed function, like as: SW-Ring™ redundancy ring network, VLAN, Trunking, Quality of Service, Speed control, port mirroring, fault alarm and firmware upgrade online. SW-Ring™ can bring your Ethernet to intelligent redundancy.
Standard Industry design, can satisfied every requirement of the industry scene. All components used industry grade, it takes products high reliability. It provided wide voltage power supply input. SWRing™ is designed as a rapid redundancy network arithmetics. It provided recover technology for fault of rapid redundant network, the recovery time<20ms.
-
IT-ES6116-IM-8F
(English)- Leggi tutto8-ports 10/100M Ethernet + 8-ports 100Base-FX(SC/ST/FC) Managed Industrial Ethernet Switch.
The IT-ES6116-IM-8F is an industrial grade, managed and redundancy Ethernet switch which supports 8 Ethernet ports and 8 Fiber ports. It provided some kinds of advanced network managed function, like as: SW-Ring™ redundancy ring network, VLAN, Trunking, Quality of Service, Speed control, port mirroring, fault alarm and firmware upgrade online. Standard Industry design can satisfied every requirement of the industry scene. All components used industry grade, it takes products high reliability.
SW-Ring™ is an arithmetic designed as a rapid redundancy network. It provided recover technology for fault of rapid redundant network, the recovery time<20ms. Product accorded to CE, FCC standard and Industry grade 4 design requirement, support 2 redundant power input and 1 channel relay alarm output, and -40~75°C working temperature, can meet all kinds of Industrial environment requirement.
-
(English) IT-ES6116-IM
(English)- Leggi tutto16-ports 10/100M Managed Industrial Ethernet Switch.
The IT-ES6116-IM is an industrial grade, managed and redundancy Ethernet switch which supports 16 Ethernet ports. It provided some kinds of advanced network managed function, like as: SW-Ring™ redundancy ring network, VLAN, Trunking, Quality of Service, Speed control, port mirroring, fault alarm and firmware upgrade online. Standard Industry design, can satisfied every requirement of the industry scene. All components used industry grade, it takes products high reliability.
SW-Ring™ is an arithmetic designed as a rapid redundancy network. It provided recover technology for fault of rapid redundant network, the recovery time<20ms. Product accorded to CE, FCC standard and Industry grade 4 design requirement, support 2 redundant power input and 1 channel relay alarm output, and -40~75°C working temperature, can meet all kinds of Industrial environment requirement.
You must belogged in to post a comment.