IT-EMC-320PFC Series
320 Watts Single Output with active PFC Series
- Universal AC input (90~264Vac)
- Built-in active PFC,PF>0.95
- Withstand 300Vac surge input for 5 sec
- High efficiency, long life and high reliability
- Output protection: SCP/OLP/OPP
- Wide operating ambient temperature (-20~65℃)
- Operating altitude up to 5000m
- PCB soldering side with conformal coating
- All using 105 ℃ long life electrolytic capacitor
- 100% full load burn-in test
- Built-in cooling fan speed control
- 3 years warranty
- Description
- Technical Specifications
- Block Diagrams
- Graphs & Curves
- Mechanical Drawings
- Download / Documentation
- Contact US / Requests
Description
320 Watts Single Output with active PFC Series
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
TECHNICAL SPECIFICATIONS
| MODEL | IT-EMC-320PFC-12II | IT-EMC-320PFC-24II | IT-EMC-320PFC-36II | IT-EMC-320PFC-48II | ||
|---|---|---|---|---|---|---|
| OUTPUT | DC Output | 12V | 24V | 36V | 48V | |
| Rated Current | 25A | 13A | 8.9A | 6.7A | ||
| Current Range Note 1 | 0~25A | 0~13A | 0~8.9A | 0~6.7A | ||
| Ripple and Noise | 0~65C | ≤200mV | ≤150mV | ≤200mV | ≤150mV | |
| Note 2 | -20~0C | ≤250mV | ≤200mV | ≤200mV | ≤200mV | |
| Voltage ADJ. Range | 10~15V | 20~27V | 32~40V | 42~53V | ||
| Voltage Accuracy | ±2.0% | ±1.0% | ||||
| Line Regulation | ±0.5% | |||||
| Load Regulation | ±2.0% | ±1.0% | ||||
| Set-up Time | ≤2S (230VAC input, Full load); ≤4S (120VAC input, Full load) | |||||
| Hold up Time | ≥10mS (120/230Vac input, Full load) | |||||
| Temperature Coefficient | ±0.03%/℃ | |||||
| Overshoot and Undershoot | <5.0% | |||||
| INPUT | Voltage Range | 90Vac~264Vac,120Vdc~370Vdc | ||||
| Frequency Range | 47Hz--63Hz | |||||
| Power Factor(Typical) | PF > 0.98/120VAC PF > 0.95/230VAC | |||||
| Efficiency ( Typical) @ 230Vac | ≥84.5% | ≥87% | ≥86.5% | ≥87.5% | ||
| AC Current (max.) | < 4.5A | |||||
| Inrush Current (Typical) | <50A@220Vac <30A@110Vac Cold start | |||||
| Leakage Current | Input—output: ≤0.25mA Input—PG: ≤3.5mA (input 264Vac, 63Hz) | |||||
| PROTECTION | Over Load | 27~35A | 14.5~19A | 9.345~13.35A | 7.3~10A | |
| Protection type: Hiccup mode, auto recovery | ||||||
| Over power | 324~420W | 358~456W | 336~480W | 350~180W | ||
| Protection type: Hiccup mode, auto recovery | ||||||
| Short Circuit | Long-term mode, auto recovery | |||||
| ENVIRONMENT | Operating amb. Temp. & Hum. | .-20℃~65℃; 20%~90%RH No condensing(refer to the derating curve) | ||||
| Storage Temp. & Hum. | .-40℃~85℃; 10%~95%RH No condensing | |||||
| Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,Y, Z axes | |||||
| SAFETY &EMC | Safety Standards | UL60950-1 2 nd Ed; IEC 60950-1:2005(2 nd Ed) ;EN60950-1:2006 | ||||
| (Note 3) | Withstand Voltage | Primary-Secondary: 3.0KVac/10mA .Primary-PG: 1.5KVac/10mA. Secondary-PG: 0.5KVdc/10mA. | ||||
| Isolation Resistance | 10M ohms | |||||
| EMI Conduction & Radiation | Compliance to EN55022, EN55024, FCC PART 15 Class B | |||||
| EMS Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; | |||||
| OTHERS | MTBF (MIL-HDBK-217F) | More than 200,000Hrs (25℃, Full load) | ||||
| Dimension (L*W*H) | 199×99×50mm | |||||
| Packing | 12PCS/CTN, 11.6KGS, 0.04CBM | |||||
| Cooling method | Cooling by forced air (built-in DC fan) |
NOTES:
1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
Product Datasheet
Related products
-

IT-SS200LM-IRL
- Read more- Highway monitoring system
- PTZ monitoring system
- Ports
- Forest Fire Prevention
- Infrared imaging
- Military application
-

IT-232D
- Read moreIT-232D is a kind of RS-232 system communication extending product. This type of product auto sense serial rate transmission rate, no external power needed, optic electric isolation 2500V, be applicable in tough environment. Transmission distance at 9,600bps is 2,000m, stable performance. IT-232D has 2500 volts of isolation twice the rating of most isolators to protect RS-232 equipment from lightning strikes, accidental high voltage shorts and ground loops.
-

IT-IPS-618-IM-2F-4-POE
- Read more4-ports 10/100Base-T(x) (POE) + 2-ports 100Base-FX + 2-ports 10/100Base-T(x).
IT-IPS-618-IM-2F-4-POE is an industrial grade, managed and redundancy Ethernet switch. The switch provides 4 ports 10/100M Ethernet PoE, 4 ports 10/100M Ethernet and 2 ports fast Ethernet optical, which 4 ports Ethernet supports POE function (IEEE 802.3af/at). It provided some kinds of advanced network managed function, like as: SW-Ring™ redundancy ring network, VLAN, Trunking, Quality of Service, Speed control, port mirroring and fault alarm. SW-Ring™ can bring your Ethernet to intelligent redundancy. The -40~75℃ working temperature, can meet all kinds of Industrial environment requirement and provide the solution of the economy.
-

IT-IPS-319-IU-1GC-4-POE
- Read more4-ports 10/100Base-T(x) (POE) + 4-ports 10/100Base-T(x) + 1-port Gigabit Combo.
IT-IPS-319-IU-1GC-4-POE is an industrial grade, unmanaged POE switch. The switch provides 8 ports 10/100M Ethernet and 1 ports combo Gigabit SFP slots or 10/100/1000Base-T(X) ports, which 4 ports Ethernet supports POE function (IEEE802.3af/at). The switches are classified as power source equipment (PSE), and when used in this way, the switches enable centralization of the power supply, providing up to 30 watts of power per port and reducing the effort needed for installing power. The switches can be used to power IEEE802.3af/at standard devices (PD), eliminating the need for additional wiring.
It support CE, FCC standard, adopt industry standard design, IP40 protection, rugged high-strength metal case, power supply input (48VDC). The switch support IEEE802.3/ IEEE802.3u/ IEEE802.3x/ with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing, the -40~75℃ working temperature, can meet all kinds of Industrial environment requirement, providing reliable and economic solution for your industrial Ethernet network.

Italiano



Warning: Undefined variable $user_ID in /web/htdocs/www.intellisystem.it/home/Intellisystem/wp-content/themes/sportlife/comments.php on line 83
You must belogged in to post a comment.